Abstract

The present work focuses on Experimental investigation of heat transfer and friction factor characteristics of horizontal circular pipe using internal threads of pitch 100mm, 120mm and 160mm with air as the working fluid. The transitional flow regime is selected for this study with the Reynolds number range 7,000 to 14,000. The horizontal aluminum pipe was subjected to constant and uniform heat flux. The experimental data obtained were compared with those obtained from plain Horizontal pipe. The effects of internal threads of varying depth on heat transfer and friction factor were presented. Based on the same pumping power consumption, the pipe with internal threads possesses the highest performance factors for turbulent flow. The heat transfer coefficient enhancement for internal threads is higher than that for plain pipe for a given Reynolds number. The use of internal threads improved the performance of horizontal circular pipe. Keywords - Enhancement, internal threads, heat transfer and turbulent flow. I. INTRODUCTION Heat exchangers are used in different processes ranging from conversion, utilization & recovery of thermal energy in various industrial, commercial & domestic applications. Some common examples include steam generation & condensation in power & cogeneration plants; sensible heating & cooling in thermal processing of chemical, pharmaceutical & agricultural products; fluid heating in manufacturing & waste heat recovery etc. Increase in Heat exchanger's performance can lead to more economical design of heat exchanger which can help to make energy, material & cost savings related to a heat exchange process. The need to increase the thermal performance of heat exchangers, thereby effecting energy, material & cost savings have led to development & use of many techniques termed as Heat transfer Augmentation. These techniques are also referred as Heat transfer Enhancement or Intensification. Augmentation techniques increase convective heat transfer by reducing the thermal resistance in a heat exchanger. Use of Heat transfer enhancement techniques lead to increase in heat transfer coefficient but at the cost of increase in pressure drop. So, while designing a heat exchanger using any of these techniques, analysis of heat transfer rate & pressure drop has to be done. Apart from this, issues like long-term performance & detailed economic analysis of heat exchanger has to be studied. To achieve high heat transfer rate in an existing or new heat exchanger while taking care of the increased pumping power, several techniques have been proposed in recent years. Generally, heat transfer augmentation techniques are classified in three broad categories: active methods, passive method and compound method. A compound method is a hybrid method in which both active and passive methods are used in combination. The compound method involves complex design and hence has limited applications. M. Sozen and T.M. Kuzay numerically studied the enhanced heat transfer in round tubes filled with rolled copper mesh at Reynolds number range of 5,000-19,000. With water as the energy transport fluid and the tube being subjected to uniform heat flux, they reported up to ten fold increase in heat transfer coefficient with brazed porous inserts relative to plain tube at the expense of highly increased pressure drop. Q. Liao and M.D. Xin carried out experiments to study the heat transfer and friction characteristics for water, ethylene glycol and ISOVG46 turbine oil flowing inside four tubes with three dimensional internal extended surfaces and copper continuous or segmented twisted tape inserts within Prandtl number range from 5.5 to 590 and Reynolds numbers from 80 to 50,000. They found that for laminar flow of VG46 turbine oil, the average Stanton number could be enhanced up to 5.8 times with friction factor increase of 6.5 fold compared to plain tube. D. Angirasa performed experiments that proved augmentation of heat transfer by using metallic fibrous materials with two different porosities namely 97% and 93%. The experiments were carried out for different Reynolds numbers (17,000-29,000) and power inputs (3.7 and 9.2 W). The improvement in the average Nusselt number was about 3-6 times in comparison with the case when no porous material was used. Fu et al. experimentally demonstrated that a channel filled with high conductivity porous material subjected to oscillating flow is a new and effective method of cooling electronic devices. The experimental investigations of Hsieh and Liu reported that Nusselt numbers were between four and two times the bare values at low Re and high Re

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call