This study presents the results of the evaluation of the purity of medical oxygen obtained by adsorption technology with pressure fluctuations, taking into account the variability of the parameters of the incoming air, and the results of the correlation analysis of data obtained from the monographs of the European and American Pharmacopoeias. The quality of oxygen obtained from air that meets sanitary standards and under conditions of the “worst case,” while fixing the time of the output of the slip signal of monoxide and carbon dioxide as marker gases, was assessed. The slip time under the experimental conditions was 13 h 22 min. The composition of the gas produced by installation was analyzed. Impurities of nitrogen, argon, and water were recognized as predominant quantitatively. Nitrous gases and sulfur dioxide were not detected. A comparative assessment of the data on medical oxygen (93%) presented in the European EP 8. 0 (No. 2455) and the American USP 38-NF (No. 4180) pharmacopeias showed that no single approach is available to assess the quality of 93% medical oxygen in pharmaceutical practice worldwide. The authors of the above-mentioned pharmacopeias note that installations for obtaining 93% medical oxygen, implementing adsorption technology with pressure fluctuations, must be equipped with gas-analytical devices to quantify the level of at least two impurities: carbon monoxide and dioxide. In general, the data obtained indicate that when obtaining 93% medical oxygen by adsorption technology with pressure fluctuations from air corresponding to sanitary and hygienic indicators (clean), the resulting gas did not contain impurities requiring quantitative assessment and/or identification. If oxygen in its pure form is rarely supplied to the patient, its further dilution to 40%–60% is more often required, and the content of hypothetically possible impurities becomes negligible. However, the technology of air separation on molecular sieves is a complex physicochemical (thermodynamic) process, and its effectiveness depends on the component composition of the incoming air, which may change when working under unfavorable environmental conditions in various locations. In this regard, medical oxygen production plants that implement this technology must employ gas-analytical devices to quantify the level of carbon dioxide and carbon monoxide impurities without fail.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.