Abstract

In order to solve the problems that the driver is threatened by accidental falling objects during forklift operation, according to the requirements of international standard ISO 6055:2004 for dynamic load test of forklift roof guard, the explicit dynamic calculation model of dynamic load simulation test was established based on LS-DYNA, and the dynamic load test was carried out at the same time. The maximum permanent deformation of roof guard is 13.5mm and 11.8mm, respectively, in the simulation and test results of dynamic load. The simulation analysis and test results show that this forklift roof guard has good deformation resistance and safety performance. And the data consistency is good, both of which meet the requirements of test standards. The results provide more design schemes and references for the structure of forklift roof guard.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.