Abstract
99mTc-stannous methylene diphosphonate (99mTc-MDP) bone single-photon emission computed tomography/computed tomography (SPECT/CT) imaging plays a crucial role in various clinical applications. Many strategies have been developed to reduce the injection activity and procedure time, improve the patient experience and reduce their anxiety prior to and during SPECT imaging. This study aimed to evaluate the SwiftScan mode and its effect on image quality, and diagnostic performance of malignant skeletal lesions in bone SPECT image. 99mTc-MDP SPECT/CT scans were acquired from the National Electrical Manufacturers Association (NEMA) phantom with a sphere-to-background ratio of 10:1, and 69 patients were enrolled in this retrospective study. The patients who showed abnormal uptake of focal 99mTc-MDP on whole-body bone planar scans, underwent local SPECT/CT scans. The image comparison and analysis were performed in three acquisition modes: SwiftScan; SwiftScan-50% (the SwiftScan mode with a 50% reduction in acquisition time); and step-and-shoot (SS). The image mean count, coefficient of variation (COV), radioactive concentration, and signal-to-background ratio (SBR) were measured for each phantom image. Visual assessment (using a 5-point Likert scale), semi-quantitative analysis [to determine the COV, mean of the standard uptake value (SUVmean), maximum of the standard uptake value (SUVmax), and SBR], and receiver operating characteristics (ROC) curve analysis were performed for clinical assessment. The SwiftScan mode obtained better quality images than the SwiftScan-50% and SS modes, and it also had better sphere clarity and lower background COVs (P<0.05). The mean counts of the SwiftScan, and the corresponding radioactive concentration and SBR were significantly higher than those of the SwiftScan-50% and SS (P<0.05), except in relation to the 13-10 mm spheres. A total of 101 abnormal 99mTc-MDP uptake skeletal lesions were included in the clinical study. The SwiftScan had significantly higher visual scores than both the SwiftScan-50% and SS (P<0.001). Additionally, there were significantly higher visual scores in the SwiftScan-50% than SS (P<0.05). The SwiftScan also had a lower COV, indicating reduced image noise. The SUVmax, SUVmean, and SBR for the skeletal lesions were significantly higher in the SwiftScan than the other two modes (P<0.05). The optimal diagnostic cut-off values of the SUVmax for identifying malignant skeletal lesions in the SwiftScan, SwiftScan-50%, and SS were 17.95, 14.75, and 9.94, respectively, but there was no significant difference among the three modes in terms of their differential diagnostic performance (all P>0.05). The SwiftScan showed significant improvements in image quality and the semi-quantitative analysis of bone SPECT imaging. It reduced the scanning time by 50% without compromising the image quality or diagnostic performance. These findings provide valuable insights that may inform the clinical application of the SwiftScan, enhancing qualitative and quantitative diagnosis in bone SPECT imaging.
Published Version
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.