Abstract
This paper describes the main characteristics of monolithic silica aerogel and its application in evacuated superinsulating aerogel glazing including the evacuation and assembling process. Furthermore, the energetic benefit of aerogel glazing is quantified. In evacuated aerogel glazing the space between the glass panes is filled with monolithic silica aerogel evacuated to a rough vacuum of approximately 1–10 hPa. The aerogel glazing does not depend on use of low emissive coatings that have the drawback of absorbing a relatively large part of the solar radiation that otherwise could reduce the space heating demand in residential buildings. The U-value of the glazing can be designed to meet the required value by increasing the monolithic silica aerogel thickness without the need for additional layers of glass. An aerogel glazing with 20 mm glass distance can reach a U-value below 0.5 W/(m 2 K) combined with a solar energy transmittance above 0.75.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.