Abstract
Electrical life tests in a dc contactor are performed under DC4 and DC5 conditions. Results from our observations and erosion measurements are compared for different silver-based contact materials. For the device used a relation can be established between the arc energy and material loss and transfer. The erosion mechanism during the make operation determines the overall arc erosion to a larger than expected extent. Silver nickel 90/10 stands out as the contact material with the lowest erosion rate under both conditions.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: IEEE Transactions on Components, Hybrids, and Manufacturing Technology
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.