Abstract

Electromigration threshold has been measured for unpassivated damascene Al(Cu) interconnects by drift experiments on Blech-type test structures, and results are compared to equivalent plasma-etched lines. When using a damascene implementation, the critical product of current density and stripe length increases significantly. As a result, the incubation period, needed for Cu depletion beyond a critical length, is increased over a wide temperature range (155–230 °C). This is shown to be an intrinsic effect, directly controlling the relative electromigration performance of both metallization schemes.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.