Abstract
The electromigration threshold in copper interconnects is reported in this study. The length-dependent electromigration degradation rate is observed and quantified in the temperature range of 295–400 °C. Based on the Blech electromigration model [I. A. Blech, J. Appl. Phys. 47, 1203 (1976)], a simplified equation is proposed to analyze the experimental data from various combinations of current density and interconnect length, as well as to estimate the electromigration threshold product of current density and line length, (jL)th, at a certain temperature. The resulting (jL)th value appears to be temperature dependent, decreasing with increasing temperature in the tested range between 295 and 400 °C.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.