Abstract

We measured electromigration incubation time and ionic drift velocity of copper interconnect using the Kawasaki-Hu test structure in the temperature range of 255-350/spl deg/C. To estimate the electromigration threshold product of current density and line length, electromigration tests were performed with current densities in the range of 1.9-7.7 MA/cm/sup 2/. Measured results indicate a remarkable incubation time of void growth in the direction of line, and it depends on the square of the current density. On the other hand, the drift velocity appears to be a linear dependent of current density. Consequently, both contributions must be considered in the lifetime estimation of operating condition. The critical product of the test structure is 7735A/cm at 300/spl deg/C.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.