Abstract

Background:QT interval dispersion (QTd) measured from the surface ECG has emerged as the most common noninvasive method for assessing heterogeneity of ventricular repolarization. Although QTd correlates with dispersion of monophasic action potential duration at 90% repolarization and with dispersion of recovery time recorded from the epicardium, total T‐wave area, representing a summation of vectors during this time interval, has been shown to have the highest correlation with these invasive measures of dispersion of repolarization. However, recent clinical studies suggest that the ratio of the second to first eigenvalues of the spatial T‐wave vector using principal component analysis (PCA ratio) may more accurately reflect heterogeneity of ventricular repolarization. Methods:To better characterize the ECG correlates of surface ECG measures of heterogeneity of ventricular repolarization and to establish normal values of these criteria using an automated measurement method, the relations of QRS onset to T‐wave offset (QTod) and to T‐wave peak (QTpd) dispersion and the PCA ratio to T‐wave area and amplitude, heart rate, QRS axis and duration, and the QTo interval were examined in 163 asymptomatic subjects with normal resting ECGs and normal left ventricular mass and function. QTod and QTpd were measured by computer from digitized ECGs as the difference between the maximum and minimum QTo and QTp intervals, respectively. Results:In univariate analyses, a significant correlation was found between the sum of the T‐wave area and the PCA ratio (R =−0.46, P < 0.001), but there was no significant correlation of the sum of T‐wave area with QTod (R = 0.11, P = NS) or QTpd (R=0.09, P = NS). There were only modest correlations between QTod and QTpd (R = 0.45) and between the PCA ratio and QTod (R = 0.29) and QTpd (R = 0.49) (each P < 0.001). In stepwise multivariate linear regression analyses, the PCA ratio was significantly related to the sum of T‐wave area, T‐wave amplitude in aVL, and to female gender (overall R = 0.54, P < 0.001), QTod correlated only with the maximum QTo0 interval (R = 0.39, P < 0.001), and QTpd was related to heart rate and QRS axis (overall R = 0.36, P <0.001). In addition, the normal interlead dispersion of repolarization as measured by QTod was significantly greater than dispersion measured by QTod (23.5 ± 11.5 ms vs 18.3 ± 11.2 ms, P < 0.001). Conclusions: These findings provide new information on ECG measures of heterogeneity of repolarization in normal subjects, with a significantly higher intrinsic variability of Q to T‐peak than Q to T‐offset dispersion and only modest correlation between these wo measures. The independent relation of the PCA ratio to the sum of T‐wave area suggests that the PCA ratio may be a more accurate surface ECG reflection of the heterogeneity of ventricular repolarizat on. A.N.E. 2000;5(1):79–87

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.