Abstract

This investigation examined how titanium ion implantation pre-treatment affects the residual stress of TiN coatings on M2 high-speed steel. Ions were implanted by metal plasma ion implantation. The adhesion strength of the TiN coatings was enhanced by pre-treatment that implanted Ti into the M2 tool steel substrate. The implanted substrate functioned as a buffer layer between the deposited TiN and the tool steel substrate, resulting in variations of the residual stress. The residual stress determined by glancing-angle XRD demonstrates that the deposited TiN films on ion-implanted substrates exhibited reduced compressive stress, from − 3.95 to − 2.41 GPa, which corresponded to a decrease in the grain size of the TiN films. The texture of the TiN film was clearly transformed from the preferred orientation of (220) to (111), subsequently enhancing wear resistance against a tungsten ball.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.