Abstract

To investigate the effects of low tube voltage on coronary plaques and pericoronary fat assessment, and to compare their extent among various levels of low voltage. Patients were recommended for high-pitch low-tube voltage coronary computed tomography angiography (CCTA), and they were included if they had poor image quality and were referred to a conventional CCTA. The patients were classified into a low-voltage group (with 70-kV, 80-kV, and 90-kV subgroups) and a conventional group (100/120 kV). Their total plaque and subcomponent volumes and pericoronary fat attenuation index (FAI) were measured. A total of 1002 image slices (from 65 patients and 74 plaques) were included, including 21, 31, 13, 4, and 61 patients in the 70-kV, 80-kV, 90-kV, 100-kV, and 120-kV groups respectively. The CT values of noncalcified plaques in the conventional and low-voltage groups were 54.6 ± 21.3 HU and 31.5 ± 22.6 HU, respectively (p < 0.05). Compared with the conventional group, the necrotic core and calcification volume were increased, and the fibrolipid volume, periplaque, and right coronary artery FAI were decreased in the low-voltage group and its subgroups (p < 0.001). The magnitude of changes in fibrous and calcification volumes increased in the 70-kV subgroup compared with that in the 90-kV subgroup (p < 0.05). Low tube voltages, particularly of 70 kV, have a significant effect on coronary plaque and FAI. The effect of low voltage on plaque composition is characterized by a polarization pattern, i.e., a decrease in fibrolipid (medium density) and an increase in necrotic core (low density) and calcification (high density). Our results highlight the comparability and repeatability of plaque and pericoronary fat assessments facilitated by the same or a similar tube voltage. It is necessary to carry out studies on the specificity threshold of low tube voltage at each level. • Low tube voltage had a significant effect on coronary plaque and pericoronary fat, particularly 70 kV. • The effect of low tube voltage on plaque composition shows the shift from medium-density mixed components to low- and high-density components. • It is necessary to correct the specificity threshold or attenuation difference for low tube voltage at each level.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.