Abstract

Accurate determination of the charge transport characteristics of amorphous metal-oxide transistors requires the mitigation of the effects of contact resistance. The use of additional electrodes as voltage probes can overcome contact resistance-related limitations and yields accurate charge carrier mobility values, trap depths and temperature and carrier density dependencies of mobility as well as trap depths. We show that large differences in measured charge carrier mobility values are obtained when such contact resistances are not factored out. Upon exclusion of the contact resistance, the true temperature dependence of charge carrier mobility appears in the form of two clearly distinct mobility regimes. Analyzing these revealed mobility regions leads to a more accurate determination of the underlying transport physics, which shows that contact resistance-related artefacts yield incorrect trends of trap depth with gate voltage, potentially leading to a misconstruction of the charge transport picture. Furthermore, a comparison of low- and high-mobility samples indicates that the observed effects are more general.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.