Abstract

Various kinds of optical fibers and related optical components for fusion diagnostics were irradiated with 14-MeV neutrons from OKTAVIAN or RTNS-II. This report shows typical fusion neutron irradiation effects on them and their hardness levels to mean 14-MeV neutron fluences at which their important performance degrades 10%. Also experimental formulas for fusion neutron induced backgrounds of scintillators and a photomultiplier tube are given by fitting their pulse height distributions for 14-MeV neutrons with a summation of exponential functions. These data and formulas are useful for the estimation of lifetimes and background levels of optical fusion diagnostic systems which may be located in the 14-MeV neutron environment of a fusion reactor.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.