Abstract
Commercially available detectors and related components for fusion diagnostics were irradiated with 14-MeV neutrons from OKTAVIAN or RTNS-II. Spectral response of the detectors to 14-MeV neutrons was measured, and experimental formulas for fusion neutron-induced backgrounds of the detectors are given by fitting their pulse height distributions with a summation of exponential functions. This paper also shows typical neutron irradiation effects on the related optical and electronic components and their hardness levels to mean 14-MeV neutron fluences at which their important performance degrades 10%. These data and formulas are useful for the estimation of lifetimes and background levels of fusion diagnostic systems which may be located in the 14-MeV neutron environment of a fusion reactor.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.