Abstract
Objective To investigate the safe time of sterile equipments used in laminar flow operating room.Methods In ten operations ( Class Ⅰ ) which last 8 or more hours,we sampled preoperative air,surgery equipments 4 h,6 h,8 h pre and intra-operatively,and surgical personnel' s hands for bacterial culture.Results There was no growth of bacteria in the sampling of preoperative air,surgical personnel's hands and surgical instruments during operation,pass rate was 100%.Conclusions The sterile equipments used in the same operation could be used safely for 8 hours in operating room where the condition of Level 100 laminar flow reached. Key words: Surgical intruments; Sterilization; Effective time
Published Version
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.