Abstract
Objective. This study evaluated the biologic result of forces induced by a misfitting prosthetic superstructure on implants placed in a New Zealand white rabbit tibia model. Study design. Nine rabbits had two dental implants placed in both right and left proximal tibias. After 6 weeks, one animal was sacrificed for baseline integration data, and the remaining animals had fitting or misfitting prosthetic superstructures attached to the implants for 12 weeks. Implants were evaluted clinically, radiographically, and histomorphometrically at the scanning electron microscopic level. Results. No clinical, radiographic, or histomorphometric evidence exists of integration failure with implants subjected to superstructure strain, although bone remodeling is noted. Conclusions. Given the limitations of sample size, animal model used, duration of prosthetic superstructure attachment, and loading confounders possible, the study of prosthetic framework misfit must be evaluated with another animal model, such as an intraoral primate model, to determine the relationship between clinical performance and histologic findings.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Oral Surgery, Oral Medicine, Oral Pathology, Oral Radiology, and Endodontology
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.