Abstract

The aim of this invitro study was to examine the potential impact of different curing times of 3D-printed orthodontic aligners on their cytotoxicity. Some 60 samples of aligner material were directly 3D printed using Tera Harz TC-85 DAC resin and randomly allocated to three different curing time groups (14, 24 and 50 min). Zendura FLX samples were used as control. The samples were incubated in saliva for 14 days, and then the supernatant was collected. Human gingival fibroblasts (HGF-1)-CRL2014 were used to evaluate potential cytotoxicity. Furthermore, HGF-1 cells were plated on the samples as well as on a glass control sample. After 72 h of growth, their viability was tested. Compared with the glass, only the 50-min curing time markedly reduced fibroblast cell growth. Additionally, a negative linear trend was observed between curing time and fibroblast growth. In comparison with the aligner control group, all samples, including the aligner control samples, exhibited a significant reduction in the viability of human fibroblasts when exposed to saliva. 3D directly printed aligners showed a cytotoxic effect similar to that of thermoformed conventional aligners in terms of fibroblasts growth. A linear trend was found between curing time and cells growth, indicating that directly printed aligners could exhibit higher cytotoxicity if exposed to a longer curing time. This dependence on curing time underscores the importance of following a strict manufacturing process.