Abstract

ABSTRACT A series of model scale experiments were conducted to study the fire development in a ro-ro deck with various opening geometries. The experiments were performed in a 1/8 reduced scale model with a heptane pool fire as fire source. Experimental results show that both the ventilation factor and the opening position affect the fire development. The critical opening ratio for the fire to self-extinguish is 4%, with the opening locating at the bottom of the side walls while no self-extinction is found for other tests. A higher opening position and a larger opening height provide better flow exchange between the deck and the ambient, but this effect is only obvious for 4% opening. Numerical study shows that Fire Dynamic Simulator used with default simple settings underestimates the fire development and yields an early extinction when fire self-extinction occurs. For freely developed fire with large openings, FDS gives more close results to experiments.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.