Abstract
This paper describes a control system design method concerning feedback and feedforward control to cancel disturbance forces, for two kinds of active vibration control devices. One is the active vibration absorber (AVA) utilizing a fixed point for a civil structure such as a bridge, and the other is the active dynamic vibration absorber (ADVA) utilizing an auxiliary mass for a buildinglike structure. We have built two test rigs to simulate large structures with an AVA or an ADVA. In order to carry out fast computation, including the estimation of disturbances, we have used a digital signal processor (DSP). In conclusion, we found that the disturbance forces are perfectly cancelled and the output zeroing is actually realized when the disturbance frequency is exactly equivalent to the design frequency of the observer. We have confirmed that the proposed disturbance cancellation control is very useful for active vibration control.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: TRANSACTIONS OF THE JAPAN SOCIETY OF MECHANICAL ENGINEERS Series C
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.