Abstract

The possibility of measurement of fuel ratio from the DT/DD reaction ratio with a neutron spectrometer in the International Thermonuclear Experimental Reactor was studied. The results of neutron transport calculations using the Monte Carlo N-particle [MCNP, a general Monte Carlo N-particle transport code, version 4C, LA-13709, edited by J. F. Briesmeister, Los Alamos National Laboratory, 2000] code system indicated the possibility of DD spectrum separation from the scattered/energy-degraded neutrons derived from DT neutrons by selection of the measurement location and collimator design. A time-of-flight spectrometer was used in this study. An experiment using DD and DT neutrons from an accelerator was conducted at the Japan Atomic Energy Agency Fusion Neutronics Source facility. Using a sophisticated circuit with three discriminators for the first detector, separation of DD and DT neutron components of the spectrum in the megahertz region was confirmed experimentally.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.