Abstract

Pharmaceutical aerosol systems present a significant challenge to computational fluid dynamics (CFD) modeling based on the need to capture multiple levels of turbulence, frequent transition between laminar and turbulent flows, anisotropic turbulent particle dispersion, and near-wall particle transport phenomena often within geometrically complex systems over multiple time scales. Two-equation turbulence models, such as the k−ω family of approximations, offer a computationally efficient solution approach, but are known to require the use of near-wall (NW) corrections and eddy interaction model (EIM) modifications for accurate predictions of aerosol deposition. The objective of this study was to develop an efficient and effective two-equation turbulence modeling approach that enables accurate predictions of pharmaceutical aerosol deposition across a range of turbulence levels. Key systems considered were the traditional aerosol deposition benchmark cases of a 90-degree bend (Re=6,000) and a vertical straight section of pipe (Re=10,000), as well as a highly complex case of direct-to-infant (D2I) nose-to-lung pharmaceutical aerosol delivery from an air-jet dry powder inhaler (DPI) including a patient interface and infant nasal geometry through mid-trachea (500<Re<7,000). Of the k−ω family of models, the low Reynolds number (LRN) shear stress transport (SST) approach was determined to provide the best agreement with experimental aerosol deposition data in the D2I system, based on an improved simulation of turbulent jet flow that frequently occurs in DPIs. Considering NW corrections, a new correlation was developed to quantitatively predict best regional values of the y+limit, within which anisotropic NW turbulence is approximated. Considering EIM modifications, a previously described drift correction approach was implemented in pharmaceutical aerosol simulations for the first time. Considering all model corrections and modifications applied to the D2I system, regional relative errors in deposition fractions between CFD predictions and new experimental data were improved from 19–207% (no modifications) to 2–15% (all modifications) with a notable decrease in computational time (up to ∼15%). In conclusion, the highly efficient two-equation k−ω models with physically realistic corrections and modifications provided a viable, efficient and accurate approach to simulate the transport and deposition of pharmaceutical aerosols in complex airway systems that include laminar, turbulent and transitional flows.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.