Abstract

On the analysis of literary sources and working processes of a positive displacement pump we established that a hydrolic diode in positive displacement pumps improves their reliability and their most efficient application is in pumps in which the process of reverse flow into the working cavity into the discharge line is insignificant in time, for example, in spur rotary pumps. We established on comparing the results of a numerical experiment on the flow of a viscous incompressible fluid in a hydrolic diode, that the k-w model most accurately describes the fluid flow in a diaphragm hydrolic diode both quantitatively and qualitatively. The performed parametric analysis of the influence of the main parameters on the fluid flow in the hydrolic diode and the diodicity proved that the distance between the hydrolic diode plates should be within 35–40 mm; the angle of inclination of the plates to the body of the hydrolic diode should be 20°−30°; the number of pairs of plates should be within 7–9 pcs.