Abstract
We studied using an ammonium peroxodisulfate as the oxidizing reagent instead of potassium hexacyanoferrate(III) on the 4-aminoantipyrine spectrometry for the determination of phenol. Suitable color development was obtained by the addition of 1 - 5 mL of ammonium peroxodisulfate solution (pH 10, 220 mmol/L) and 2 mL of 4-aminoantipyrine solution (98 mmol/L) to a 100 mL sample solution at pH 10 buffered with an ammonium chloride - ammonia solution (9.8 mol/L). The proposed procedure was applied to methyl benzoate extraction for determining small amounts of phenol in water. Results obtained by the proposed method were in agreement with that by the JIS method.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.