Abstract

A spark-source mass spectrometric (SSMS) method capable of determining traces of hydrogen in micro-volumes of metals was developed by using a pointed metal probe technique. The hydrogen background was decreased to μg g −1 levels by the combination of a method in which the sample in the ion source is baked under vacuum at 323–343 K for more than 25 ks and a liquid nitrogen or liquid helium cryogenic pump method. This method was applied to the analysis of austenitic stainless steels at μg g −1 hydrogen levels, and the relative standard deviation was within 20% for samples with hydrogen concentrations ranging from 2 to 4 μg g −1. The relative sensitivity coefficent was 2.3 (Fe=1).

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.