Abstract A pulse polarographic method is described for determining traces of gallium in arsenic compounds. Interference from the reduction of the arsenic matrix was eliminated by a prior distillation of arsenic as arsenic(III)chloride or arsenic(V) bromide. The pulse polarographic sensitivity was 2.10−8 M in 6.5 M sodium perchlorate + 0.5 M sodium thiocyanate at pH 2, allowing the determination of as little as 0.03 gallium in a 1 g sample.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.