Abstract

In this paper, a method for the determination of formaldehyde in carbon-coated air purifying material by ultraviolet spectrophotometry was established. The test determined the detection limit, lower limit of determination, precision and accuracy of the method. When the sampling quality is 2.0g, the detection limit of the method is 0.0412μg, the recovery is 98.4%∼105.8%, and the precision RSD is 2.646% ∼ 3.894%. The results show that this method is suitable for the determination of formaldehyde in carbon-coated air purifying material.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.