Abstract

A procedure for the determination of Cd, Pb and Cu in different wine samples after simple sample preparation on a mercury film electrode (MFE) by potentiometric stripping analysis (PSA) is presented. In 150 German wine samples collected in 1993/94 the following values were found: Cd mean: 0.63 ng/mL (range: 0.003– 0.98 ng/mL); Pb mean: 50 ng/mL (range: 4–254 ng/mL); Cu mean: 250 ng/mL (range: 50–394 ng/mL).

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.