Abstract
The authors regret that they have identified a miscalculation in the original article that required the authors to provide corrective additions that are listed below. Specifically the authors determined that the shingle uplift pressure, p1=12.5Pa, used in the original article (Croom et al., 2015) is associated with a 40km/h (25mph) wind velocity instead of 145km/h (90mph). A miscalculation of pressure values due to inaccurate unit conversion was the source of the misstatement. The corrected interior uplift pressure is p1=183Pa for a 145km/h (90mph) wind velocity and p1=507Pa for a 241km/h (150mph) wind velocity. Additional simulation results have been performed for the corrected pressures and the results are reported in this Corrigendum.