Abstract
A grazing incidence constant deviation monochromator with a spherical concave grating was fabricated for use with undulator radiation. It has a simple scanning mechanism with fixed entrance and exit slits, as well as fixed directions of incident and exit beams. It has been installed into an undulator beamline at IMS. Synchrotron radiation from a bending section also can be introduced into the monochromator by using premirrors. The energy resolution of the monochromator is better than 70 meV at the photon energy of 94 eV with 10-μm slits, when the bending magnet synchrotron radiation is used. The spot size of the zeroth-order light is 1.5(v)×2.0(h) mm2 at the distance of 1.85 m behind a postmirror. The photon flux of the undulator radiation behind the exit slit is approximately 1×1012 photons/s at the peak, when both the entrance and exit slits are 100 μm (ΔE=0.08 eV) and the stored current is 50 mA.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.