Abstract

The undulator based beamline X13A at the National Synchrotron Light Source has been commissioned recently. The X13 undulator has an 8 cm period, and its first harmonic is in the energy range of 200–700 eV at the nominal ring energy of 2.5 GeV. The beamline uses horizontally deflecting optics. It consists of a SiC plane mirror, a water cooled entrance slit, a spherical grating, and two fixed exit slits. A flux of more than 1012 photons/s at 450 eV has been measured at X13A with an aluminum-oxide photodiode with a 200 μm entrance slit, a 500 μm exit slit, and a ring current of 242 mA. A VF3 absorption spectrum recorded at X13A shows the monochromator resolving power is at least 1000 at ∼500 eV with 30 μm entrance and exit slits, in agreement with calculations. The X13A beamline will be used for x-ray coherence studies, spectroscopy, and multilayer reflectivity measurements as well as for x-ray instrumentation diagnostics.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.