Abstract
The article presents a new approach for investigation of spatial distributions of soft and hard X-rays emitted from dense magnetized plasma. The approach is based on the application of tomographic methods to the X-ray emission reconstruction in a plasma focus (PF) device. Quantitative investigation of the anisotropy of the reconstructed X–ray plasma emissivity may help to explain the nature of fusion reaction mechanisms in a PF device. The aim of this work is to present a conceptual design of a novel dual-energy X-ray emission tomographic system dedicated to the PF-24 plasma focus device. The system, which enables the simultaneous registration of soft and hard X-rays, is composed of three X‐ray pinhole cameras. Each camera is equipped with a pair of 16-element Si photodiode arrays arranged in two layers separated by an aluminum attenuator. The Geant4 code was used to optimize the layout and parameters of the applied detectors. In addition, a method of tomographic reconstruction from a sparse data set provided by the experimental setup has been presented.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.