Abstract
In this paper we report computational fluid dynamics and thermal stress finite element analyses of a T-joint component as used in a Swiss nuclear power plant under realistic loading conditions and simplified boundary conditions. In this report the focus is on the thermal stress analyses, and therefore only those fluid dynamics simulations used for thermal stress analyses are presented. The local stress amplitudes, simulated using elastic finite element simulations, are compared to a regulatory fatigue life curve to estimate the local distribution of low cycle fatigue damage and crack initiation probability in the T-joint. The case studies reported here have been selected with the purpose of analyzing the different ways in which the fluid structure interaction induces thermal stress in the mixing tee. In case I only the thermal stress induced by the mixing turbulence is simulated, i.e. with constant mass flow rate boundary conditions. In case II a peak in the flow rate in the main pipe, typical for transient (startup) plant conditions, is addressed and analyzed in detail. Only in the latter case is low cycle fatigue cracking to be expected in the form of non-propagating (i.e. not throughwall) surface cracks or crazing.
Published Version
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.