Abstract

To investigate the diagnostic value of multislice spiral CT (MSCT) and MRI in occult fracture of knee joint with meniscus and ligament injury. From January 2020 to March 2021, 63 patients with knee occult fracture with meniscus and ligament injury, including 41 males and 22 females, aged from 21 to 67 years old, with an average of (44.35±8.77) years old, the course of disease ranged from 1 to 6 days, with an average of (4.64±1.75) days, the body mass index (BMI) was (19.85±2.78) kg/m2. MSCT and MRI data of 63 patients were collected and statistically analyzed to evaluage their diagnist value. The detection of MRI for occult knee fravtures with meniscus and ligament injury, joint cavity effusion, bone marrow edema, and articular surface injury were 100.00% (63/63), 95.24% (60/63), 42.86% (27/63) and 36.51% (23/63), respectively. The detection rates of MSCT were 49.21% (31/63), 41.27% (26/63), 0.00% (0/63) and 1.59% (1/63), respectively, significantly lwver than that of MRI (P<0.05). The diagnostic sensitivity, specificity and accuracy of MRI were significantly higher than those of MSCT(P<0.05). The sensitivity, specificity and accuracy of magnetic resonance imaging in the diagnosis of occult fracture of knee joint with meniscus and ligament injury are significantly better than that of MSCT. MRI has higher accuracy in the diagnosis of peripheral tissue diseases such as joint cavity, articular surface and bone marrow, and can reduce the risk of clinical misdiagnosis.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call