Abstract
The goal of this study is to determine whether any difference in corneal biomechanical properties exists between Sjögren's syndrome dry eye patients and healthy subjects. Thirty-one patients diagnosed with Sjögren's syndrome and associated dry eye manifestations and 44 healthy individuals were included in the study. Ultrasonic pachymetry (UP) was used to measure central corneal thickness (CCT). Corneal biomechanical parameters were obtained using ocular response analyzer (ORA). The main parameters assessed were corneal hysteresis (CH), corneal resistance factor (CRF), Goldmann correlated intraocular pressure (IOPg) and corneal compensated IOP (IOPcc). A Student's t-test for independent groups was performed to compare the mean of these variables between both groups. Mean CH values in Sjögren's syndrome and healthy subject eyes were 10.1mmHg and 11.18mmHg respectively, representing a statistically significant difference (P=0.003). No other variable measured differed between cases and controls (P>0.05). Mean CRF values were 9.51mmHg and 10.37mmHg respectively, and mean CCT measured by UP in cases and controls was 527.41μm and 552.51μm respectively. Sjögren's syndrome can influence corneal biomechanical properties, specifically CH. ORA measurements should be considered of interest in the evaluation of Sjögren syndrome subjects.