Abstract
The paper aims to provide a comprehensive study on the compositional optimization of high-conductive multifunctional fiber-reinforced cement mortars (FRCMs). Therefore, the effects of three different fiber types: virgin carbon fibers (VCFs), recycled carbon fibers (RCFs), and brass-plated steel fibers (BSFs), added at a broad range of concentrations, as 0.05%, 0.1%, 0.2%, 0.4%, 0.8%, 1.2%, and 1.6% by volume, on the mechanical, electrical and durability properties of FRCMs have been compared. The results showed that RCFs increase the flexural and tensile splitting strength up to 100%, whereas BSFs improve the compressive strength by 38%. Moreover, the fibers decrease both the capillary water absorption and the drying shrinkage by 39%. Electrical conductivity tests show that RCFs decrease the electrical resistivity of mortars up to one order of magnitude, in addition to a percolation threshold between 0.1 and 0.2 vol%.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.