Abstract

Article history: Received June 25, 2012 Received in Revised form November 6, 2012 Accepted 30 November 2012 Available online 30 November 2012 A new and simple method for the preconcentration and spectrophotometric determination of trace amounts of nickel was developed by cloud point extraction (CPE). In the proposed work, dimethylglyoxime (DMG) was used as the chelating agent and Triton X-114 was selected as a non-ionic surfactant for CPE. The parameters affecting the cloud point extraction including the pH of sample solution, concentration of the chelating agent and surfactant, equilibration temperature and time were optimized. Under the optimum conditions, the calibration graph was linear in the range of 10-150 ng mL with a detection limit of 4 ng mL. The relative standard deviation for 9 replicates of 100 ng mL Ni(II) was 1.04%. The interference effect of some anions and cations was studied. The method was applied to the determination of Ni(II) in water samples with satisfactory results. © 2013 Growing Science Ltd. All rights reserved.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.