Abstract

A practical example of the use of single‐structure diffusion pumping groups in an experiment requiring hydrocarbon‐free, ultrahigh vacuum is presented. With the use of proper vacuum procedures and careful foreline design and operation, but with no exotic hardware or liquid nitrogen, we have demonstrated that such a pump could provide vacuum that was ‘‘clean,’’ i.e., which had no residual pump‐oil contamination to a partial pressure below 10−8 mbar. Their use is thus compatible, at least in peripheral vacuum chambers, with standard ‘‘UHV‐surface science’’ processes. We discuss our vacuum system in detail, and present a review of the literature on the production of clean vacua with diffusion pumps.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.