Abstract

Characterization of charge heterogeneity of recombinant monoclonal antibodies (mAbs) requires high throughput analytical methods to support clone selection and formulation screens. We applied the NanoPro technology to rapidly measure relative charge distribution of mAbs in early stage process development. The NanoPro is a multiplexed capillary-based isoelectric immunoassay with whole-column imaging detection. This assay offers specificity, speed and sensitivity advantages over conventional capillary isoelectric focusing (CIEF) platforms. After CIEF, charge variants are photochemically immobilized to the wall of a short coated capillary. Once immobilized, mAbs are probed using a secondary anti-IgG conjugated with horseradish peroxidase. After flushing away excess reagents, secondary antibodies bound to their targets are then detected by chemiluminescence upon incubation with peroxidase reactive substrates. Charge heterogeneity as determined by chemiluminescence was similar to that measured by conventional CIEF technology with absorbance detection for purified mAbs and contaminated mAbs derived directly from host cellular extract. Upon method optimization, the automated CIEF immunoassay was applied to several mAbs of varying isoelectric points, demonstrating the suitability of NanoPro as a rugged high-throughput product characterization tool. Furthermore, qualification of detection sensitivity, precision, and dynamic range are reported with discussion of its advantages as an alternative approach to rapidly characterize charge variants during process development of mAbs.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call