Abstract

Avoiding gate oxide damage due to excessive wafer charging has always been an issue with high current implanters. On the other hand, whether it is caused by shrinking of device dimensions, or its use as a backup for high current applications, charging level awareness becomes the primary limiting factor for running higher beam currents in medium current implanters. Often a cautious approach results in lower machine throughput. To the present, flooding the wafer with low energy electrons from electron showers (E-Shower) has been the widely accepted means of reducing wafer charging. The effectiveness of the E-shower in reducing charging as a function of primary ion current has been investigated in Eaton's medium current ion implanter. Extensive testing included over 180 bare and photoresist coated CHARM(R)-2 charge monitors. Optimum shower settings will be presented and discussed in the light of CHARM-2 results and product split lot yields.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call