Abstract
American Electrical Power's Conesville plant had historically prevented ice buildup at a water intake by routing warm water from a once-through cooling system to the intake. In 2012, this system was retired and warm water was no longer available for de-icing. A numerical study was conducted to evaluate design alternatives to reduce ice transport to the intake. An Eulerian–Lagrangian model was used to predict the hydrodynamics and ice trajectories. A porous media model accounted for the ice accumulation in the trash racks. The model was capable of predicting the observed flow pattern. Predicted velocities compared well with measurements using large-scale particle image velocimetry (LSPIV). According to the model, sediment control vanes, placed in front of the intake to alleviate sediment ingestion, favour the ice transport to the intake. Based on model results, a mitigation plan to be implemented during several phases was elaborated.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.