Abstract

Simple SummaryThere is a growing interest in using milk mid-infrared (MIR) spectrometry to obtain new phenotypes to assist in the complex management of dairy farms. These predictive values can be erroneous for many reasons, even if the prediction equations used are accurate. Unfortunately, there is no quality protocol routinely implemented to detect those abnormal predictive values in the database recorded by dairy herd improvement (DHI) organizations, except for fat and protein contents. However, for financial and practical reasons, it is unfeasible to adapt the quality protocol commonly used in milk laboratories to improve the accuracy of those traits. So, this study proposes three different statistical methods that would be easy to implement by DHI organizations to detect abnormal values and limit the spectral extrapolation in order to improve the accuracy of MIR-based predictive values.The use of abnormal milk mid-infrared (MIR) spectrum strongly affects prediction quality, even if the prediction equations used are accurate. So, this record must be detected after or before the prediction process to avoid erroneous spectral extrapolation or the use of poor-quality spectral data by dairy herd improvement (DHI) organizations. For financial or practical reasons, adapting the quality protocol currently used to improve the accuracy of fat and protein contents is unfeasible. This study proposed three different statistical methods that would be easy to implement by DHI organizations to solve this issue: the deletion of 1% of the extreme high and low predictive values (M1), the deletion of records based on the Global-H (GH) distance (M2), and the deletion of records based on the absolute fat residual value (M3). Additionally, the combinations of these three methods were investigated. A total of 346,818 milk samples were analyzed by MIR spectrometry to predict the contents of fat, protein, and fatty acids. Then, the same traits were also predicted externally using their corresponded standardized MIR spectra. The interest in cleaning procedures was assessed by estimating the root mean square differences (RMSDs) between those internal and external predicted phenotypes. All methods allowed for a decrease in the RMSD, with a gain ranging from 0.32% to 41.39%. Based on the obtained results, the “M1 and M2” combination should be preferred to be more parsimonious in the data loss, as it had the higher ratio of RMSD gain to data loss. This method deleted the records based on the 2% extreme predictions and a GH threshold set at 5. However, to ensure the lowest RMSD, the “M2 or M3” combination, considering a GH threshold of 5 and an absolute fat residual difference set at 0.30 g/dL of milk, was the most relevant. Both combinations involved M2 confirming the high interest of calculating the GH distance for all samples to predict. However, if it is impossible to estimate the GH distance due to a lack of relevant information to compute this statistical parameter, the obtained results recommended the use of M1 combined with M3. The limitation used in M3 must be adapted by the DHI, as this will depend on the spectral data and the equation used. The methodology proposed in this study can be generalized for other MIR-based phenotypes.

Highlights

  • Since the 1980s, milk contents like fat and protein have been predicted using milk midinfrared (MIR) spectrometry

  • As the milk laboratories involved in the milk analysis for the milk payment and the routine recording of dairy cows performance are the same, the ring test is a great opportunity for dairy herd improvement (DHI) organizations to ensure a high quality of the fat and protein phenotypes used in their breeding selection programs

  • All milk samples were analyzed on four Bentley FTS instruments (Bentley, MN, USA) to predict the contents (g/dL of milk) of fat and protein that were corrected using the slope and bias estimated from ring tests

Read more

Summary

Introduction

Since the 1980s, milk contents like fat and protein have been predicted using milk midinfrared (MIR) spectrometry. Due to the direct economic link between those MIR predictions and farm profitability, most milk laboratories follow a quality-assurance procedure proposed by the Internal Dairy Federation during what is most commonly called the “ring test”. During this test, identical sets of modified milk samples (i.e., often 10 milk samples having a large variation of fat content) are measured using MIR spectrometers in the different laboratories. The ring test has a cost due to the creation and sending of milk samples, the reference chemical analysis, and the laboratory comparisons This cost is the price to ensure the best predictive values and accuracy for the fat and protein phenotypes predicted by MIR. As the milk laboratories involved in the milk analysis for the milk payment and the routine recording of dairy cows performance are the same, the ring test is a great opportunity for dairy herd improvement (DHI) organizations to ensure a high quality of the fat and protein phenotypes used in their breeding selection programs

Objectives
Methods
Results
Discussion
Conclusion
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have