Abstract
A polychrometer-type motional Stark effect (MSE) diagnostic technique, originally developed for the Alcator C-Mod tokamak, has been extended and applied to the Korea Superconducting Advanced Tokamak Research (KSTAR) device, the long-pulse superconducting tokamak, for the first time. It demonstrates a successful in situ subtraction of the polarized reflections off the vacuum vessel wall, sometimes up to half the total signal in some sightlines. To avoid the secondary neutral beam emission that may contaminate conventional beam-into-gas calibrations, a new approach, where the beam-into-gas measurements are made at various torus pressures with fixed vacuum fields, has been devised, which is possible with the stable superconducting coil systems of KSTAR. The validity of this new calibration scheme has been checked via plasma jog experiments. The experimental evidence of the polarized background light and the necessity of its correction in the MSE measurements made in KSTAR are presented as well.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.