Abstract

Abstract The objective of the paper was to determine the level of circumferential stress in a wall of an open milk tank and to assess the tank wall degree of utilization according to the FKM Guideline calculation algorithm − Analytical Strength Assessment of Components, Made of Steel Cast Iron and Aluminium Materials in Mechanical Engineering. (German: FKM – Forschungskuratorium für Maschinenbau). The stress level in the tank wall was determined based on analytical calculations and numerical method using the FEA – Finite Elements Analysis. Numerical calculations were made in FEMAP with NX NASTRAN Solver (NASTRAN – NASA Structure Analysis). Similar stress values were found using two independent calculation methods. The difference between obtained stress values does not exceed 2%. Based on the FKM algorithm, the safety factor jges = 1.4 and static capacity of the tank wall ask = 19.7% were calculated.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.