Abstract
The present study focuses on the use of coupled shear walls with and without dampers for resisting seismic loads. Multistory structures with and without shear walls are analysed. Different parameters, such as the structure's base shear, storey drift, storey displacement, storey stiffness, and storey shear, are evaluated, and a comparative study is performed. It is observed that coupled shear walls with fluid viscous dampers reduce storey drift by 24% and storey displacement by 45% when compared to buildings without shear walls. A coupled shear wall with a damper has a 29% higher stiffness than a coupled shear wall without a damper, thus performing effectively in resisting lateral forces induced by an earthquake.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.