Abstract

In this contribution we focus on an innovative use of the well known lock-in thermography (LIT) technique. The main purpose of this paper is to show the possible use of the LIT technique in transient analysis of power devices. We show how the LIT technique can be used to image the current distribution in Unclamped Inductive Switching (UIS) tests and experimentally verify if current filamentation occurs. A significant number of experimental measurements on 1000 A peak current – 900 V maximum sustainable voltage Trench-IGBT is reported and discussed. The correlation between the sudden decrease in collector voltage during UIS test and filamentary current conduction inside the device has been demonstrated. Given the results of this analysis, an improved understanding of the reliability in UIS tests for the analyzed devices has been obtained confirming LIT technique as a useful tool for power devices analysis.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.