Abstract
Particulate matter from coal and stone operations is a primary air pollution source. The traditional nozzle requires high-pressure conditions, and the atomization droplets are large and uneven. This paper aims to study a linear Laval nozzle and investigate the impact of water pressure on atomization performance. The volume of fluid (VOF) model and discrete phase model (DPM) of Fluent are used to simulate the internal and external fields of the nozzle and analyze the velocity, droplet size, and atomization angle. The results show that the optimized water pressure parameters are 0.1 MPa with an air pressure of 0.5 MPa. Droplets in the middle are smaller, while those on the sides are larger. Compared to traditional nozzles, the water pressure is reduced by over 90%, and the Sauter mean diameter (SMD) decreases by over 50%. Moreover, the theoretical spray angle increases by approximately 150%.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: International Journal of Engineering and Technology Innovation
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.