Abstract

This study analyzed the concentrations of TSP and CO at 2 different sites in Kota Kendari. Measurement of TSP levels at the site I, Jl. MT Haryono, the highest concentration occurred in the morning (79 g/Nm3) compared to midday (51 g/Nm3) and in the afternoon (46 g/Nm3). Judging from the quality standards based on PP No. 41 of the year 1999, the concentration of TSP and CO on Jl. MT Haryono has not exceeded the quality standard. However, according to PP No. 22 of the year 2021, the CO level has reached the quality standard threshold. At site II, the TSP level at Jl. The highest Achmad Yani occurred in the morning at 63 g/Nm3 compared to midday (28 g/Nm3) and in the afternoon (35 g/Nm3) while CO levels in the morning, afternoon, and evening remained stable at 12,000 g/Nm3. Based on PP No. 41 of the year 1999, the concentrations of TSP and CO in ambient air on Jl. Ahmad Yani has not exceeded the quality standard, but if it is reviewed based on PP no. 22 of the year 2021, CO levels have exceeded the quality standard threshold. Physical factors (temperature, wind speed, and humidity) and anthropogenic factors such as motorized vehicle traffic are maybe contributions.

Highlights

  • Penelitian ini menganalisis kosentrasi Total Solid Particulate (TSP) dan CO pada 2 titik berbeda di Kota Kendari

  • This study analyzed the concentrations of TSP and CO at 2 different site in Kota Kendari

  • MT Haryono, the highest concentration occurred in the morning (79 g/Nm3) compared to midday (51 g/Nm3) and in the afternoon (46 g/Nm3)

Read more

Summary

METODOLOGI Alat dan Bahan

Perangkat alat dan bahan yang digunaka dalam penelitian ini adalah hand tally counter, environmental tester, baterai, carbon monoxide meter, particular counter, camera, dan ATK. Menyimpan filter ruangan yang sudah dikondisikan dengan temperature 350C dengan kelembaban relative ≤ 50% selama 1 jam; 3. Menempatkan filter pada filter holder dan menghubungkan alat HVAS dengan sumber catudaya, selanjutnya menghidupkan alat pengambil contoh uji; 6. Selama 24 jam ±1 jam, memantau dan mencacat laju alir udara serta temperature setiap jam, pastikan lajur alir udara berada pada rentang 1,1 m3/menit sampai dengan 1,7m3/menit. 8. Menyimpan filter pada ruangan yang sudah dikondisikan dengan temperature 150C sampai dengan 350C dan kelembaban relatif ≤ 50% serta biarkan selama 24 jam. Hasil pengukuran kadar Total Solid Particulate (TSP) dan karbon monoksida (CO) dibandingkan dengan baku mutu kualitas udara ambien menurut Peraturan Pemerintah Republik Indonesia Nomor 41 Tahun 1999 (Pemerintah Pusat, 1999) dan Peraturan Pemerintah No 22 Tahun 2021(Pemerintah Pusat, 2021)

BT dan titik II yaitu di depan Kantor Grapari
Waktu Motor
Jalan Ahmad Yani
Percepatan Angin
Environment Tester
DAFTAR PUSTAKA
Perlindungan dan Pengelolaan Lingkungan
Anthropogenic Emission Inventory of Criteria
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call