Abstract
Temperature sensitive electrical parameters (TSEP) provide an indirect and noninvasive method for on-line junction temperature estimation of power semiconductor devices. It is known that the fundamental of TSEP-based methods is to calibrate the relationship between TSEP and junction temperature in advance. However, the calibration methods in the literature need to open the module, require pretesting, or record the operating data of a converter in the entire power rating range, which are inconvenient in field applications. This article proposes an on-line and noninvasive calibration method by measuring the data at three operating states that are already existed in the regular converter operation. It is achieved by measuring the accessible heatsink/case temperature and TSEP during converter regular operation. The concept, implementation, and error analysis of the proposed method are presented in this article. Experimental verification is given to prove the effectiveness, accuracy, and convenience of the proposed method.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.