Abstract
Imaging the brain of a freely moving small animal using positron emission tomography (PET) while simultaneously observing its behaviour is an important goal for neuroscience. While we have successfully demonstrated the use of line-of-response (LOR) rebinning to correct the head motion of confined animals, a large proportion of events may need to be discarded because they either 'miss' the detector array after transformation or fall out of the acceptance range of a sinogram. The proportion of events that would have been measured had motion not occurred, so-called 'lost events', is expected to be even larger for freely moving animals. Moreover, the data acquisition in the case of a freely moving animal is further complicated by a complex attenuation field. The aims of this study were (a) to characterise the severity of the 'lostevents' problem for the freely moving animal scenario, and(b) to investigate the relative impact of attenuation correction errors on quantitative accuracy of reconstructed images. A phantom study was performed to simulate the uncorrelated motion of a target and non-target sourcevolume. A small animal PET scanner was used to acquirelist-mode data for different sets of phantom positions. The list-mode data were processed using the standard LOR rebinning approach, and multiple frame variants of this designed to reduce discarded events. We found that LOR rebinning caused up to 86 % 'lost events', and artifacts that we attribute to incomplete projections, when applied to a freely moving target. This fraction was reduced by up to 18 % using the variant approaches, resulting in slightly reduced image artifacts. The effect of the non-target compartment on attenuation correction of the target volume was surprisingly small. However, for certain poses where the target and non-target volumes are aligned transaxially in the field-of-view, the attenuation problem becomes more complex and sophisticated correction methods will be required. We conclude that there are limitations with the LOR rebinning approach and simplified attenuation correction for freely moving animals requiring the development and validation of more sophisticated approaches.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Australasian Physical & Engineering Sciences in Medicine
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.